Well Completions Solutions

Universal control key device for sliding sleeves operations

Automatic tool deactivation system
System to prevent jamming of moving parts
Adjustment of activation pressure
Deactivation of dies when fluid circulation through the tool decreases
General Description

The hydraulically activated tool is designed to move the sleeve to in open and close positions.
The tool is designed to guarantee reliable engagement and movement of the sleeve under a great force created by the fluid pressure inside sealed working cavities.
When running the tool in the hole in the transport position, it cannot be unintentionally activated and engaged as the maximum external diameter enables the slip dies to be locked deep inside.
Activation pressure can be optionally adjusted according to customer requirements.

Features & Benefits
Automatic tool release system
Anti-jamming system for moving parts
Activation pressure adjustment
Deactivation of slip dies with decreasing fluid circulation through the tool
Specifications
Conditional diameter of casing string, in 4,5
Maximum overall diameter in transport position, in, max. 2,56
Connection thread from above, GOST 633-80 48
Diameter of lever mechanism after activation, in  4,21
Actuator activation pressure, kgf/cm2 (without taking into account pressure losses in the tubing string) 51±10,2
Fluid flow rate through the tool required to reach the activation pressure, l/min, not less* 200
Number of actuator joints, pcs. 3
Overall length, in 424
Maximum overpressure inside the IP housing, kgf/cm2 561
Maximum control force of the coupling mating part, not more, tf 1,0
Maximum column unloading on the tool during lowering and manipulation, tf 20,0
Maximum tensile load on the tool body, not more, tf 150
Maximum working medium temperature, °C 20
Weight, kg

 

Conditional diameter of casing string, mm 114,3
Maximum overall diameter in transport position, mm, max. 65
Connection thread from above, GOST 633-80 48
Diameter of lever mechanism after activation, mm  107
Actuator activation pressure, MPa (without taking into account pressure losses in the tubing string) 5,0±1,0
Fluid flow rate through the tool required to reach the activation pressure, l/min, not less* 200
Number of actuator joints, pcs. 3
Overall length, mm 1070
Maximum overpressure inside the IP housing, MPa 55,0
Maximum control force of the coupling mating part, not more, kN 10,0
Maximum column unloading on the tool during lowering and manipulation, kN 196,0
Maximum tensile load on the tool body, not more, kN 150
Maximum working medium temperature, °C 20
Weight, kg